Degradation Kinetics and Mechanical Studies of Intumescent Coated Cotton Fabric

Authors

  • Satish Kumar Department of Chemistry, University College, Kurukshetra University, Kurukshetra-136 119, India
  • Sohan Lal Department of Chemistry, Kurukshetra University, Kurukshetra-136 119, India
  • Sanjiv Arora Department of Chemistry, Kurukshetra University, Kurukshetra-136 119, India

DOI:

https://doi.org/10.6000/1929-5995.2015.04.02.2

Keywords:

Model free kinetics, Thermal Analysis, CRA, Pad-Dry Cure, MMLR.

Abstract

In the present study, cotton fabric were prepared via coating with intumescent formulations of ammonium polyphosphate (APP), guanidine nitrate, penta erythritol (PER) and metal salts at different loading levels via ‘Pad-dry cure’ method. Thermal degradation behavior of prepared cotton derivatives was investigated by thermogravimetry (TG) and differential thermal analysis (DTA) from ambient temperature to 700 oC. Dynamic TG analysis was used to study the thermal degradation behavior of samples at four different heating rates of 2, 5, 10 and 20 oC min-1 in air atmosphere. The treated cotton fabric decomposes at lower temperatures and produces higher amount of char yields. The degradation activation energy was calculated using Friedman, modified Coats-Redfern and Ozawa-Flynn-Wall (O-F-W) iso-conversional model free methods. Tensile properties of coated fabric were found to be reduced with increase in loading of intumescent formulation but there was an abrupt increase in sample coated with intumescent and silica. With the insertion of iron (Fe) metal ion along with intumescent reduces the fabric strength due to formation of metal complexes with cotton cellulose which decreases the crosslinking. The maximum flame ratardancy of CF 12APP-Si among all cotton derivatives is suggested as the flame retardancy directly proportional to char yield (22 % at 650 oC) that is highest and inversely proportional to MMLR value (8.3 % min-1), that is least among all samples. Based on thermal and kinetic studies, the optimum concentration of flame retardant is worked out.

References

Shafizadeh F, Lai YZ, Mcintyre CR. Thermal degradation of 6-chlorocellulose and cellulose-zinc chloride mixture. J Appl Polym Sci 1978; 22: 1183-93. http://dx.doi.org/10.1002/app.1978.070220503 DOI: https://doi.org/10.1002/app.1978.070220503

Bhagwan J, Arora S, Lal K. Thermal and spectroscopic studies on cellulose and its phosphorylated products in air. J Polym Mater 1990; 7: 231-7.

Arora S, Bhatnagar HL. Thermal and spectral studies of cellulose and cellulose aryl phosphates. J Polym Mater 1992; 9: 35-42.

Singh R, Arora S, Lal K. Thermal characteristics of cellulose 2-chlorophenylthiophosphate and its metal complexes. J Polym Mater 1995; 12: 263-71.

Betts KS. New thinking on flame retardants. Enviorn Health Perspect 2008; 116: A210-3. http://dx.doi.org/10.1289/ehp.116-a210 DOI: https://doi.org/10.1289/ehp.116-a210

Huang X, Zhang WD. Preparation of cellulose sulphate and evaluation of its properties. J of Fiber Bioengineering and Informatics 2010; 3: 32-9. http://dx.doi.org/10.3993/jfbi06201006 DOI: https://doi.org/10.3993/jfbi06201006

Arju SN. Use of transition metal ions to enhance flame retardancy of ammonium polyphosphate treated back coated cotton fabrics. International Journal of Engineering & Technology IJET-IJENS 2010; 10: 20-3.

Hebeish A, Waley A, El-Kashouti MA. Durable flame resistance via reaction of cotton cellulose bearing aromatic amino group with tetrakis(hydroxymethyl)phosphonium chloride. J Appl Polym Sci 1979; 23: 1803-10. http://dx.doi.org/10.1002/app.1979.070230620 DOI: https://doi.org/10.1002/app.1979.070230620

Reshetnikov I, Antonov A, Rudakova T, Aleksjuk G, Khalturinskij N. Some aspects of intumescent fire retardant systems. Polym Degrad Stab 1996; 54: 137-41. http://dx.doi.org/10.1016/S0141-3910(97)81483-8 DOI: https://doi.org/10.1016/S0141-3910(97)81483-8

Dahiya JB, Kumar K. Flame retardant study of cotton coated with intumescents: kinetics and effected metal ions. J Sci Ind Res 2009; 68: 548-54.

Langille K, Ngayen D, Veinot DE. Inorganic intumescent coating for improved fire protection of GRP. Fire Tech 1999; 35: 99-110. http://dx.doi.org/10.1023/A:1015459720909 DOI: https://doi.org/10.1023/A:1015459720909

Horrocks AR. Development in flame retardants for heat and fire resistant textiles-the role of char formation and intumescence. Polym Degrad Stab 1996; 54: 143-54. http://dx.doi.org/10.1016/S0141-3910(96)00038-9 DOI: https://doi.org/10.1016/S0141-3910(96)00038-9

Brown ME, Maciejewski M, Vyazovkin S, et al. Computational aspects of kinetic analysis Part A: The ICTAC kinetic project-data, methods and results. Thermochim Acta 2000; 355: 125-43. http://dx.doi.org/10.1016/S0040-6031(00)00443-3 DOI: https://doi.org/10.1016/S0040-6031(00)00443-3

Friedman HL. Kinetics of thermal degradation of char-forming plastics from thermogravimetry. Application to phenolic plastic. J Polym Sci Part C–Polym Symp 1964; 6: 183-95. http://dx.doi.org/10.1002/polc.5070060121 DOI: https://doi.org/10.1002/polc.5070060121

Brown AL, Dayton DC, Daily JW. A study of cellulose pyrolysis chemistry and global kinetics at high heating rates. Energ Fuel 2001; 15: 1286-94. http://dx.doi.org/10.1021/ef010084c DOI: https://doi.org/10.1021/ef010084c

Flynn JH, Wall LA. General treatment of thermogravimetry of polymers. J Res Nat Bur Stand–A. Phy Chem 1966; 70A: 487-523. DOI: https://doi.org/10.6028/jres.070A.043

Cabrales L, Abidi N. On the thermal degradation of cellulose in cotton fibres. J Therm Anal Calorim 2010; 102: 485-91. http://dx.doi.org/10.1007/s10973-010-0911-9 DOI: https://doi.org/10.1007/s10973-010-0911-9

Ming L. Crease resistant finishing of cotton fabric with a complex of fibroin and citric acid. Fibres Text East Eur 2010; 18: 86-8.

Can Y, Akaydin M. Effect of Wrinkle Resistant Finish on Cotton Fabric Properties. Indian J Fibre Text 2009; 34: 183-6.

Ramachandran T, Gobi N, Rajendran V, Lakshmikantha CB. Optimization of process parameters for crease resistant finishing of cotton fabric using citric acid. Indian J Fibre Text 2009; 34: 359-67.

Wei W, Yang CQ. Predicting the performance of durable press finished cotton fabric with infrared spectroscopy. Text Res J 1999; 34: 145-51. DOI: https://doi.org/10.1177/004051759906900210

Yang CQ. Crosslinking: a route to improve cotton, The University of Georgia AATCC, Copyright © 2013 AATCC. 2013; 1-44.

Kang In-Sook, Yang CQ, Wei W, Gary CL. Mechanical strength of durable press finished cotton fabrics: part I: effects of acid degradation and crosslinking of cellulose by polycarboxylic acids. Text Res J 1998; 68: 865-70. http://dx.doi.org/10.1177/004051759806801112 DOI: https://doi.org/10.1177/004051759806801112

Prakash Y, Mahadevaiah D, Somashekarappa H, Demappa T, Somashekar R. Microstructural parameters of HPMC/PVP polymer blends using wide angle X-ray technique. J Res Updates Polym Sci 2012; 1: 24-31. http://dx.doi.org/10.6000/1929-5995.2012.01.01.4 DOI: https://doi.org/10.6000/1929-5995.2012.01.01.4

Waichiro T. On the lowering of the tensile strength of cotton fiber caused by the intermolecular crosslinking. Bull Inst Chem Res Kyoto Univ 1971; 49: 69-79.

Gaur S, Reed TB. Prediction of cellulose decomposition rates from thermogravimetric data. Biomass Bioenerg 1994; 7: 61-7. http://dx.doi.org/10.1016/0961-9534(94)00047-W DOI: https://doi.org/10.1016/0961-9534(94)00047-W

Arora S, Kumar M, Kumar M. Catalytic effect of bases in impregnation of guanidine nitrate on poplar (populus) wood: flammability and multiple heating rate kinetic study. J Therm Anal Calorim 2012; 107: 1277-86. http://dx.doi.org/10.1007/s10973-011-1779-z DOI: https://doi.org/10.1007/s10973-011-1779-z

Kumar M, Kumar M, Arora S. Thermal degradation and flammability studies of wood coated with fly ash intumescent composites. J Indian Acad Wood Sci 2013; 10: 125-33. http://dx.doi.org/10.1007/s13196-013-0105-8 DOI: https://doi.org/10.1007/s13196-013-0105-8

Liodakis S, Antonopoulos I, Kakardakis T. Evaluating the use of minerals as forest fire retardants. Fire Safe J 2010; 45: 98-105. http://dx.doi.org/10.1016/j.firesaf.2009.11.002 DOI: https://doi.org/10.1016/j.firesaf.2009.11.002

Kumar S, Kumar M, Lal S, Kumar S, Arora S. Model free heating rate degradation kinetic studies of modified celluloses. Chem Sci Trans 2015; 4: 181-93.

Arora S, Lal S, Kumar S, Kumar M, Kumar M. Comparative degradation kinetic studies of three biopolymers: Chitin, chitosan and cellulose. Arch Appl Sci Res 2011; 3: 188-201.

Shafizadeh F, Bradbury AGW. Thermal degradation of cellulose in air and nitrogen at low temperatures. J Appl Polym Sci 1979; 23: 1431-42. http://dx.doi.org/10.1002/app.1979.070230513 DOI: https://doi.org/10.1002/app.1979.070230513

Downloads

Published

2015-07-28

How to Cite

Kumar, S., Lal, S., & Arora, S. (2015). Degradation Kinetics and Mechanical Studies of Intumescent Coated Cotton Fabric. Journal of Research Updates in Polymer Science, 4(2), 69–78. https://doi.org/10.6000/1929-5995.2015.04.02.2

Issue

Section

Articles